Manejo del Paciente con Luxación de Lente Intraocular a Cavidad Vítrea y Sutura de Lente Intraocular a Esclera con Túnel Escleral, Gore-Tex y Nudo Cow Hitch

Dra. Gabriela LópezCarasa Hernández, Dr. Nicolás Crim

Keywords : LIO luxado, fijación escleral de LIO, Gore-Tex, túnel escleral, nudo cow hitch

Citation Information : Hernández DG, Crim DN. Manejo del Paciente con Luxación de Lente Intraocular a Cavidad Vítrea y Sutura de Lente Intraocular a Esclera con Túnel Escleral, Gore-Tex y Nudo Cow Hitch. 2021; 49 (5ESP):21-32.

DOI: 10.5005/hos-10101-49502

Published Online: 12-10-2021

Copyright Statement:  Copyright © 2021; Jaypee Brothers Medical Publishers (P) Ltd.


Abstract

El objetivo de esta técnica es describir el manejo quirúrgico de la luxación de lente intraocular a cavidad vítrea, así como la técnica de fijación escleral AB para suturar un lente intraocular de cámara posterior (LIOCP) al surco ciliar con sutura de monofilamento de politetrafluoroetileno (PTFE) CV8 (Gore-Tex), utilizando túneles esclerales y nudo cow hitch. Existen importantes ventajas que nos proporciona el uso de túneles esclerales así como el uso de sutura Gore-Tex en estos pacientes, relacionados con comorbilidades y resultados a largo plazo, así mismo se propone el uso del nudo cow hitch que previene deslizamientos, aporta mayor rigidez y nos provee dos puntos de fijación en aquellos lentes con un ojal en la háptica.


PDF Share
  1. R. J. Olson, N. Mamalis, L. Werner, and D. J. Apple, “Cataract treatment in the beginning of the 21st century,” American Journal of Ophthalmology, vol. 136, no. 1, pp. 146–154, 2003.
  2. H. V. Gimbel, G. P. Condon, T. Kohnen, R. J. Olson, I. Halkiadakis, “Late in-the-bag intraocular lens dislocation: incidence, prevention, and management,” Journal of Cataract and Refractive Surgery, vol. 31, no. 11, pp. 2193– 2204, 2005.
  3. Davison JA. Capsule contraction syndrome. J Cataract Refract Surg 1993;19(5):582-589.
  4. W. R. F. Böke and H. C. A. Krüger, “Causes and management of posterior chamber lens displacement,” American Intra- Ocular Implant Society Journal, vol. 11, no. 2, pp. 179– 184, 1985.
  5. Yasuda A, Ohkoshi K, Orihara Y, Kusano Y, Sakuma A, Yamaguchi T. Spontaneous luxation of encapsulated intraocular lens onto the retina after a triple procedure of vitrectomy, phacoemulsification, and intraocular lens implantation. Am J Ophthalmol 2000;130(6):836-837.
  6. Hayashi K, Hayashi H, Matsuo K, Nakao F, Hayashi F. Anterior capsule contraction and intraocular lens dislocation after implant surgery in eyes with retinitis pigmentosa. Ophthalmology 1998;105(7):1239-1243.
  7. Yang S, Nie K, Jiang H, Feng L, Fan W. Surgical management of intraocular lens dislocation: A meta-analysis. PLoS One. 2019 Feb 20;14(2): e0211489.
  8. Tran THC, Zaier D, Proença J, Rouland JF. Posterior segment Intra-Ocular Implant (IOL) dislocation: Predisposing factors, surgical management, outcome analysis. J Fr Ophtalmol. 2020 Dec;43(10):1062-1068.
  9. Subasi S, Yuksel N, Karabas VL, Yilmaz Tugan B. Late in-the-bag spontaneous IOL dislocation: risk factors and surgical outcomes. Int J Ophthalmol. 2019 J” {]=un 18;12(6):954-960.
  10. Gimbel HV, Condon GP, Kohnen T, Olson RJ, Halkiadakis I. Late in-the-bag intraocular lens dislocation: incidence, prevention, and management. J Cataract Refract Surg 2005;31(11):2193-2204.
  11. Rowson NJ, Bacon AS, Rosen PH. Perfluorocarbon heavy liquids in the management of posterior dislocation of the lens nucleus during phakoemulsification. Br J Ophthalmol 1992; 76: 169–170.
  12. Ernst BJ, Velez-Montoya R, Kujundzic D, Kujundzic E, Olson JL. Experimental measure of retinal impact force resulting from intraocular foreign body dropped onto retina through media of differing viscosity. Clin Exp Ophthalmol. 2013 Jul;41(5):471-5.
  13. Khan MA, Gupta OP, Smith RG, Ayres BD, Raber IM, Bailey RS, Hsu J, Spirn MJ. Scleral fixation of intraocular lenses using Gore-Tex suture: clinical outcomes and safety profile. Br J Ophthalmol. 2016 May;100(5):638-43.
  14. Ni S, Wang W, Chen X, Wu X, He S, Ma Y, Xu W. Clinical observation of a novel technique: transscleral suture fixation of a foldable 3-looped haptics one-piece posterior chamber intraocular lens implantation through scleral pockets with intact conjunctiva. BMC Ophthalmology (2019) 19:105.
  15. Botsford BW, Williams AM, Conner IP, Martel JN, Eller AW. Scleral Fixation of Intraocular Lenses with Gore-Tex Suture: Refractive Outcomes and Comparison of Lens Power Formulas. Ophthalmol Retina. 2019 Jun;3(6):468- 472.
  16. Lewis JS. Ab externo sulcus fixation. Ophthalmic Surg 1991;22(11): 692–695.
  17. Lyu J, Zhao P. Simplified ab externo fixation technique to treat late dislocation of scleral-sutured polymethyl methacrylate intraocular lenses. Eye (2016) 30, 668–672.
  18. Can E, Koçak N, Yücel ÖE, Gül A, Öztürk HE, Sayin O. Abinterno scleral suture loop fixation with cow-hitch knot in posterior chamber intraocular lens decentration. Indian J Ophthalmol. 2016 Feb;64(2):124-6.
  19. Hoffman RS, Fine IH, Packer M. TECHNIQUES: Scleral fixation without conjunctival dissection. J Cataract Refract Surg 2006; 32:1907–1912.
  20. Long C, Wei Y, Yuan Z, Zhang Z, Lin X, Liu B. Modified technique for transscleral fixation of posterior chamber intraocular lenses. BMC Ophthalmology (2015) 15:127.
  21. Meyer DC, Bachmanna E, Lädermannb A, Lajtai G, Jentzsch T. The best knot and suture configurations for high-strength suture material. An in vitro biomechanical study. Orthopaedics & Traumatology: Surgery & Research 104 (2018) 1277–1282.
PDF Share